Evolution in Compact Calorimetry: The Modern C 200 h Calorimeter
The IKA C 200 h Calorimeter combines precision, reliability, and cost-efficiency in a compact design. Developed for determining the gross calorific value of liquid and solid samples, it is ideal for technical schools, universities, and industrial laboratories with lower sample throughput requirements. Its space-saving construction and affordable investment cost make it an excellent entry-level yet standards-compliant solution in combustion calorimetry.
Fully compliant with DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, and ASTM E711, the C 200 h ensures internationally recognized and reproducible results.
C 200 h Functions and Technical Features
Manual or Semi-Automated Operation
Water and oxygen filling are performed manually. For higher sample volumes, the system can be upgraded with a cooling circulator (RC 2) and C 200.RC hose for semi-automated operation.
Dynamic and Isoperibol Measurement Modes
-
Dynamic mode: approx. 8 minutes measurement time
-
Isoperibol mode: approx. 17 minutes measurement time
-
Repeatability: 0.1% RSD (1 g benzoic acid NBS39i)
High Precision Performance
-
Maximum measuring range: 40,000 J
-
Temperature resolution: 0.0001 K
-
Maximum operating temperature: 25 °C
Halogen-Resistant Decomposition Vessel (C 5012)
The catalytically active, halogen-resistant decomposition vessel made of Hastelloy is specially designed for samples containing more than 3% halogens and sulfur. The material prevents corrosion caused by high chlorine content, while the catalytically activated inner surface improves recovery rates when analyzing halogens and/or sulfur after combustion.
Standards Compliance
Designed to perform analyses according to:
DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, and ASTM E711.
Data Management and Software
The C 6040 CalWin software controls the unit and monitors measurements. Collected data can be exported and evaluated in Excel, Word, SQL, and LIMS systems. Multiple calorimeters can be operated from one PC. (CalWin sold separately.)
Scope of Delivery
-
C 200 Calorimeter Unit
-
C 5012 Halogen-Resistant Catalytically Active Decomposition Vessel
-
C 200.2 Conversion Kit for C 5012
-
C 248 Oxygen Filling Station
-
Consumables for calibration and installation
Technical Specifications
-
Measuring range: max. 40,000 J
-
Measurement modes: Dynamic (25 °C) / Isoperibol (25 °C)
-
Dynamic measurement time: approx. 8 min
-
Isoperibol measurement time: approx. 17 min
-
Repeatability: 0.1% RSD
-
Temperature resolution: 0.0001 K
-
Dimensions (W × H × D): 400 × 400 × 400 mm
-
Weight: 21 kg
-
Permissible ambient temperature: 20–25 °C
-
Permissible relative humidity: 80%
-
Protection class (DIN EN 60529): IP20
-
Interface: RS232 / Centronix printer
-
Voltage: 100–240 V
-
Frequency: 50/60 Hz
-
Power input: 120 W
Reliable and Efficient Performance
With its compact design, high precision, and strict standards compliance, the C 200 h provides an efficient and economical solution for routine calorific value analysis. Whether used for training purposes or industrial quality control, it delivers dependable results with straightforward operation.
What do you need? Simply contact us!